Reference: Model 446
SCI 446, 5kV @ 20mA AC Hipot, 6kV @ 5mA DC Hipot, Insulation Resistance, 40A AC Ground Bond Tester, CE Listed
AC/DC/IR AND GB TESTER
Reference: Model 446
AC/DC/IR AND GB TESTER
Reference: Model 294
6 kV @ 5 mA DC Hipot Tester
Reference: S3011H
30W, 70V,3A DC, 10A Pulse, Single-Channel SMU
Reference: SSA3015X Plus
Frequency range: 9 kHz to 1.5GHz. Free preamplifier, Sensitivity: -156dBm/Hz 5MHz~1.5GHz free tracking generator included, support component frequency response test. Support EMI, Digital demodulation, analog demodulation with option
Felible, High absorption rate absorber, frequency range up to 50GHz. Temperature range: -55~150 degree. Good absorption performance for both plane wave and surface wave. Application: EMC test, Antenna test, OTA test, Radar test etc
EMI anechoic and fully anechoic chambers can be supplied to suit customer requirements. We work with a leading UK manufacturer of anechoic test chambers and faraday cages to provide shielded enclosures lined with high performance anechoic (anti-echo) material. This creates an accurate, stable and repeatable testing environment for EMC and RF (wireless)...
Single phase Current rating: 16Amps Frequency range: 150kHz~30MHz LISNs fully compliant with the CISPR16 standard and issued with all calibration data.
Reference: SA3000
9KHz—3GHz range to cover EN, FCC and international standards. Powerful PC software control and automation included. 200Hz RBW and Tracking Generator options. USB interface for very simple operation. Compact and simple to use whilst including all the necessary features for self testing your own products.
Fully compliant range of CDNs High specification . No compromises. Reduce equipment costs and maximise flexi-bility due to the ‘Versatile’ benefits of the range. Just 5 models cover over 23 different cable types. Improve test productivity (and accuracy) with the ‘Enhanced’ range. Avoid time consuming pre-calibration scans and mis-match errors. Reduce...
Reference: MS-BS
Micsig STO110C (plus) or STO1104E Spare Battery 7500mA
Antenna test system cover RF band up to THz. Turn-key Project by state of art MW instrument, mechanics and Software, deliver professional service by strong engineer expertise. Not only the Antenna Test Systems, but also the Anechoic Chamber and related infrastructure construction. Adopt different test Full-range Near Field Antenna Test Ability, including...
Reference: CW-2438C
2438C A mode support one channel test, B mode for dual CH. Abundant power sensors, CW coaxial power sensor frequency up to 67GHz, Waveguide sensor support to 750GHz Max. dynamic range: 90dB High accuracy Internal calibration technology Flexible frequency response offset list settings, with high-power attenuator or high-power directional coupler to achieve...
Generate banded THz signal by Microwave band Signal source and THz doubler
Reference: CW-2438C
2438C A mode support one channel test, B mode for dual CH. Abundant power sensors, CW coaxial power sensor frequency up to 67GHz, Waveguide sensor support to 750GHz Max. dynamic range: 90dB High accuracy Internal calibration technology Flexible frequency response offset list settings, with high-power attenuator or high-power directional coupler to achieve...
Reference: SDS1104X-U
Features: 100 MHz bandwidth Real-time sampling rate up to 1 GSa/s Record length up to 14 Mpts Serial bus triggering and decoder supports protocols I2C, SPI, UART, CAN, LIN Advanced measurements on full memory (14 Mpts) Large 7-inch TFT-LCD display with 800 * 480 resolution
Reference: SDS1000X-E-FG
FG function software for SDS1000X-E oscilloscope
Reference: LB-660
Frequency Range : 0.6-6 GHz Gain, Typ: 11 dB Polarization: Linear 3dB Beamwidth, E-Plane, Range (Deg.) 33 - 92 3dB Beamwidth, H-Plane, Range (Deg.) 34-56 Cross Pol. Isolation, Typ (dB) : 25 Application: General Purpose Indoor & Outdoor, FixedSolution for: Gain Reference, Antenna Measurement, Reflector Feed, Far-field...
Reference: NTPIM-E
Features Frequency coverage: CDMA800, GSM900, DCS1800, TD-SCDMA2000, UMTS2100, LTE2600.3rd order intermodulation sensitivity is better than -168dBcTest port output power: 2 channel carrier wave signal, min. +33dBm to the max. +46dBm.Multi protections and inspection functions.Capable to test IMD3,5,7 orders of intermodulation signals.