Measurement Computing Corporation (MCC) and Data Translation (DT) DAQ products are now part of the Digilent family of test and measurement solutions. MCC and DT are leading suppliers of data acquisition solutions that are easy-to-use, easy-to-integrate, and easy-to-support.
The MCC USB-200 series are low-cost, 12-bit, multifunction DAQ devices designed for general purpose data acquisition applications. Each device features eight SE analog voltage inputs, two analog outputs, eight digital I/O, and one counter input.
USB-201 features a 100 kS/s sample rate, 8 digital I/O, and 1 counter input.
USB-202 features a 100 kS/s sample rate, 2 analog outputs, 8 digital I/O, and 1 counter input.
USB-205 features a 500 kS/s sample rate, 2 analog outputs, 8 digital I/O, and 1 counter input.
USB-201-OEM: DAQ device with 8 SE analog inputs, 12-bit resolution, 100 kS/s sample rate, 8 digital I/O, and 1 counter input. OEM version removes enclosure and screw terminals and adds headers.
USB-204-OEM: DAQ device with 8 SE analog inputs, 12-bit resolution, 500 kS/s sample rate, 8 digital I/O, and 1 counter input. OEM version removes enclosure and screw terminals and adds headers.
USB-205-OEM: DAQ device with 8 SE analog inputs, 12-bit resolution, 500 kS/s sample rate, 2 analog outputs, 8 digital I/O, and 1 counter input. OEM version removes enclosure and screw terminals and adds headers.
Key Features
USB 2.0 Hi-speed, USB bus power
4-CH simultaneous-sampling analog input, up to 2MS/s per channel
500VDC Isolation & 256M samples FIFO
Analog and digital triggering
Removable screw terminals on the module
Lockable USB cable for secure connective
Key Features
16 SE/8 DIFF analog inputs
16-bit resolution
500 kS/s sample rate
±10 V, ±5 V, ±2 V, ±1 V input ranges
Two analog outputs (USB-1608GX-2AO only)
Eight digital I/O
Two counter inputs
One timer output
No external power required
Product Compliance:
HTC: 8471.80.9000
ECCN: EAR99
Key Features
16 single-ended (SE) or eight differential (DIFF) analog input channels
Up to eight analog inputs can be configured for thermocouples measurements
24-bit resolution
1 kS/s sample rate
Two 16-bit analog output channels
Eight digital I/O channels
Two counter channels (32-bit) that count TTL pulses
500 VDC input isolation between field wiring...
Key Features
USB-2627: 16 SE analog inputs
USB-2637: 64 SE analog inputs
16-bit resolution
1 MS/s sample rate
±10 V input range
Four 16-bit analog outputs
24 digital I/O
Four counter inputs
Four timer outputs
No external power required
Key Features
8 SE/4 DIFF analog inputs
16-bit resolution
USB-231: 50 kS/s sample rate
USB-234: 100 kS/s sample rate
±10 V input range
Two 16-bit analog outputs
Eight digital I/O
One counter input
No external power required
Product Compliance:
HTC: 8471.80.9000
ECCN: EAR99
Key Features
8 SE/4 DIFF analog inputs
13-bit resolution
1 MS/s sample rate
±20 V, ±10 V, ±5 V, ±2.5 V, 0-10 V input ranges
Four 12-bit analog outputs
16 digital I/O
Two counter inputs
One timer output
No external power required
Product Compliance:
HTC: 8471.80.9000
ECCN: 3A992.a
Key Features
Four SE simultaneous analog inputs
16-bit resolution
1.33 MS/s/ch sample rate
±10 V, ±2.5 V, ±500 mV input ranges
32 digital I/O
Two analog outputs
Four counter inputs
Three quadrature encoder inputs
Two timer outputs
Key Features
USB-201 & USB-202: 100 kS/s sample rate
USB-205: 500 kS/s sample rate
USB-202 & USB-205: Two analog outputs
Eight SE analog inputs
12-bit resolution
+/-10 V input range
Eight digital I/O
One 32-bit event counter input
External pacer I/O
No external power required
Key Features
8 SE/8 DIFF simultaneous analog inputs
18-bit resolution
200 kS/s/ch sample rate
±10 V, ±5 V, 0-10 V, 0-5 V input ranges
Two 16-bit analog outputs
Four digital I/O
Two counter inputs
Two quadrature encoder inputs
Two timer outputs
No external power required
Product Compliance:
HTC: 8471.80.9000
ECCN: EAR99