Features
MICROTEST 7140 Power Analyzer is designed for single-phase AC/DC power measurement and analysis.
It features an exclusive Super Filter Function (High-pass / Low-pass / Band-pass), supporting a wide measurement bandwidth from DC, 0.2Hz to 100kHz with a high-speed 500kSPS sampling rate. With ±0.05% basic power accuracy, it offers precise measurements on key power parameters.
The compact unit comes with a 4.3” TFT LCD displaying both numeric and graphical data. It supports direct input up to 800V and 30A, with 100-order harmonic analysis and simultaneous integration measurement for enhanced efficiency. It supports low standby power testing with a 5mA current range and 10μW power resolution. Users can view waveform, bar, and trend charts, and display 4/8/16 parameters in Meter mode, including max/min monitoring. A comparator mode is also available for PASS/FAIL judgment based on user-defined thresholds.


Selection
| Model | 7140 Powar Analyzer | 7130 Power Meter |
| Frequency Range | D C , 0 . 2H z~10 0 k H z | D C , 0 . 2H z~10 0 k H z |
| Basic Measurement Accuracy | ±0 . 0 5 % | ±0 . 0 5 % |
| Sampling Rate | 5 0 0 k SP S | 5 0 0 k SP S |
| Meter Mode | ● | ● |
| Harmonic Analysis | 100th-order harmonic | 50th-order harmonic |
| Voltage and Current Waveform Display | ● | ● |
| Power Trend Graph | ● | — |
| Harmonic Bar Char t | ● | — |
Extensive Parameter Measurement
| Voltage (VRMS/ VDC/ V+PK/ V-PK) | Apparent Power(S) |
| Current (IRMS/ IDC/ I+PK/ I-PK) | Reactive Power ( Q ) |
| Frequency (VHZ/ IHZ) | Phase Angle (DEG) |
| Power(P) | Total Harmonic Distortion (THDV/ THDI/ THDW) |
| Crest Factor (CFV/ CFI) | Maximum Current Ratio (MCR) |
| Power Factor(PF) | Displacement Power Factor (DPF) |
Input
| Input | |||
| Measurement range |
Voltage |
Crest factor 3: 15V/ 30V/ 60V/ 150V/ 300V/ 600V | |
| Crest factor 6: 7.5V/ 15V/ 30V/ 75V/ 150V/ 300V | |||
| Current: Direct input | Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA/0.5A/1A/2A/5A/10A/20A(Max30A) Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA/0.25A/0.5A/1A/2.5A/5A/10A |
||
| Current External current sensor input |
Crest factor 3: 500mV/ 1V/ 2V/ 5V/ 10V | ||
| Input impedance | Voltage | Input resistance: Approx. 1.66MΩ Input capacitance:Approx. 13pF (Parallel with the resistance) |
|
| Current Direct input |
Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA |
Input resistance:Approx. 500mΩ+10mΩ(wire) Input inductance:Approx. 0.1μH |
|
| Crest factor 3: 0.5A/1A/2A/5A/10A/20A Crest factor 6: 0.25A/0.5A/1A/2.5A/5A/10A |
Input resistance: Approx. 5mΩ + 3mΩ(wire) Input inductance: Approx. 0.1μH |
||
| Current External current sensor input |
Crest factor 3: 0.5V/1V/2V/5V/10V | Input resistance: Approx. 10kΩ | |
| Continuous maximum allowable input |
BNC | Max AC 10V | |
| Voltage | Peak value 1131V | ||
| Current | Crest factor 3: 5mA/10mA/20mA/50mA/100mA/200mA Crest factor 6: 2.5mA/5mA/10mA/25mA/50mA/100mA |
Maximum current: 0.9A | |
| Crest factor 3: 0.5A/1A/2A/5A/10A/20A Crest factor 6: 0.25A/0.5A/1A/2.5A/5A/10A |
Maximum current: 30A | ||
| Line filter | Select OFF or ON(cutoff frequency at 500Hz/5kHz/100kHz), THD ON(cutoff frequency at 500Hz/ 5kHz) | ||
| Frequency filter | Select OFF or ON(cutoff frequency at 500Hz) | ||
| A/D converter | Simultaneous conversion of voltage and current inputs Resolution: 16bits, Maximum conversion rate: 500kSPS |
||
Voltage/ Current/ Active Power Accuracy
| Voltage/ Current/ Active Power Accuracy | |||
|
Voltage and Current |
Accuracy | DC | DC Accuracy ±0.05% reading ± 0.05% of range |
| 0.2Hz ≦ f < 45Hz | ±(0.1% of reading + 0.1% of range) | ||
| 45Hz ≦ f ≦ 66Hz | ±(0.05% of reading + 0.05% of range) | ||
| 66Hz < f ≦ 1kHz | (0.1% of reading + 0.1 % of range) | ||
| 1kHz < f ≦ 10kHz | ±([{0.07×(f)}% of reading] + 0.3% of range ) | ||
| 10kHz < f ≦ 100kHz | ±(0.4 % of reading + 0.4 % of range)±[{0.04×(f–10)}% of reading] | ||
| Frequency range |
Data update interval | Measurement Frequency Range | |
| 0.05s | 40Hz ~ 100kHz | ||
| 0.1s | 20Hz ~ 100kHz | ||
| 0.2s | 10Hz ~ 100kHz | ||
| 0.25s | 8Hz ~ 100kHz | ||
| 0.5s | 5Hz ~ 100kHz | ||
| 1s | 2Hz ~ 100kHz | ||
| 2s | 1.5Hz ~ 100kHz | ||
| 5s | 0.5Hz ~ 100kHz | ||
| 10s~60mins | 0.2Hz ~ 100kHz | ||
|
Active Power Accuracy |
Requirements | Same as the conditions for voltage and current. Power factor: 1 | |
| Accuracy | DC | ±(0.05% reading ± 0.05% of range) | |
| 0.1Hz ≦ f < 45Hz | ±(0.2% of reading + 0.2% of range) | ||
| 45Hz ≦ f ≦ 66Hz | ±(0.05% of reading + 0.05% of range) | ||
| 66Hz <f ≦ 1kHz | ±(0.1% of reading + 0.1 % of range) | ||
| 1kHz <f ≦ 10kHz | ±(0.1% of reading + 0.2% of range)± [{0.06×(f)}% of reading] | ||
| 10kHz < f ≦ 100kHz | ±(0.4 % of reading + 0.4 % of range)±[{0.07×(f–10)}% of reading] | ||
Integration
| Integration | |
| Mode | Manual integration mode |
| Timer | Automatically stop integration by setting a timer Selectable range: 0h00m00s ~ 9999h59m59s(0h00m00s, automatically sets to manual integration mode) |
| Count overflow | WP: 999999MWh/-99999MWh, q: 999999MAh/-99999MAh |
| Accuracy | ±(Power accuracy (or current accuracy) + 0.05% of reading) (fixed range) *In auto-range mode, measurement is not performed during range switching. The first measurement after switching and the non-measurement period are included in calculations |
| Range setting | Auto range or fixed range for Integration is available. *Refer to the "Voltage, Current, and Power Measurement" section for range switching. |
| Valid Frequency Ranges for Integration | Active power: DC to 100 kHz Current: DC to 100 kHz |
| Timer accuracy | ±0.02% |
Harmonic
| Harmonic | ||
| Measured item | 1~100 {Voltage, Current, Power, Voltage Ratio, Current Ratio, Power Ratio, Voltage Phase Angle, Current Phase Angle}, and all measurement items when THD is not enabled |
|
| Method | PLL synchronization method with Discrete Fourier Transform for harmonic analysis | |
| Frequency range | Fundamental frequency of the PLL source is in the range of 20Hz ~ 480Hz | |
| PLL source | Select voltage or current of each input element | |
| DFT data length | 4096 | |
| Accuracy | 20Hz ≦ f < 45Hz | ±(0.2% of reading + 0.2% of range) |
| 45Hz ≦ f ≦ 66Hz | ±(0.05% of reading + 0.05% of range) | |
| 66Hz < f ≦ 1kHz | ±(0.1% of reading + 0.1 % of range) | |
| 1kHz < f ≦ 10kHz | ±(0.1% of reading + 0.2% of range)± [{0.06×(f)}% of reading] | |
| 10kHz < f ≦ 48kHz | ±(0.4 % of reading + 0.4 % of range)±[{0.07×(f–10)}% of reading] | |
External Current Sensor Input
Measurement range:Crest factor 3: 0.5V/ 1V/ 2V/ 5V/ 10V
MICROTEST 7140 provides a maximum input of 800V and 30A. For current measurement needs exceeding 30A, voltage input-type current
clamps or current sensors can be purchased for testing.
| High Current Measurement Solution | |
| Clamp- on Tr ans f ormer | Cur r ent Sensor |
|
|
|
| AC 100A/ 1V | AC 500A/ 4V |
| Bandwidth 5kHz | Bandwidth 50kHz |
System
| Supply voltage | 100VAC~240VAC, 50~60 Hz |
| Power consumption | 30VA MAX |
| Display | 4.3"TFT, 800*480 |
| Remote Control Input/Output Signal | USB、RS-232、ETHERNET 10/100M |
| Memory | USB disk、Embed flash |
| Operating environment | Temperature: 13°C to 40°C Humidity: < 80%RH |
| Weight | 2.9kg |
| Dimensions | 214x115x300mm |