Recent Posts

View All
Microtest Impulse Winding Tester 7750 Series
  • Microtest Impulse Winding Tester 7750 Series
  • Microtest Impulse Winding Tester 7750 Series

Microtest Impulse Winding Tester 7750 Series

7750 Series

Advanced Impulse Winding Tester provides pulse voltage outputs of 1200V/5200V/10000V and utilizes high-speed sampling technology at 200MHz/9 bits.

Starting from AUD$ 7260

Call for availability & lead time
Description

Features

  • Lowest Inductance (≥0.1μH)
  • High voltage calibration
  • programmable impulse voltage
  • 200MHz/9bit  High Impulse Test Sampling Rate
  • Total Area Comparison
  • Differential Area Comparison
  • Corona  Comparison
  • LAPLACIAN Comparison
  • Voltage Compensation Function

MICROTEST 7750 Series is an advanced Impulse Winding Tester with a faster color display screen. It provides pulse voltage outputs of 1200V/5200V/10000V and utilizes high-speed sampling technology at 200MHz/9 bits. It offers various comparison modes such as total area, area difference, corona count, jitter count, second-order differentiation, and waveform comparison. With a testing speed of up to 10 times per second, it is ideal for high-speed production lines.

For testing small components, the optional 7750-1S tester comes with the FX-IM0001 four-wire SMD component testing fixture. It features voltage compensation to minimize voltage errors caused by wiring and equivalent inductance, ensuring accurate quality control for products with small inductance.

Specifications

Selection

Model 7750-1S 7750-1F 7750-5E 7750-5H 7750-5S 7759 7750-10S
Channel 1 1 1 1 1 9 1
Sampling Rate 200MHz/ 9bit 200MHz/ 9bit 50MHz/ 9bit 100MHz/ 9bit 200MHz/ 9bit 200MHz/ 9bit 200MHz/ 9bit
Voltage Output 10V-1200V 100V-5200V 200V-10000V
Lowest Inductance ≥ 0.1μH ≥ 0.1μH ≥ 16μH ≥ 4μH ≥ 1μH ≥ 1μH ≥ 20μH
Test Time 10 times/ Sec
Breakdown Voltage Test ● ● - - ● ● ●
LAN Interface ● ● - - ● ● ●
Waveform Analysis
Total area comparison ● ● ● ● ● ● ●
Differential area comparison ● ● ● ● ● ● ●
LAPLACIAN Comparison ● ● - ● ● ● ●
Corona comparison ● ● ● ● ● ● ●
FLUT Comparison ● ● ● ● ● ● ●
COMP Comparison ● ● ● ● ● ● ●
 

SPEC

Pulse Number Max. 32
Input Impedance 20MΩ
Measurement Statistics ●
Provides 6 waveform comparison

4a9a3807b5a4a8ff8d7db1bc70c400a1.JPG

Total area comparison

When layer short happened, the loss of power on coil increase, the resonance damping coefficient increase, resonance amplitude decrease, the total area decrease. These are the basic parameters we check layer short.

 

By calculating and comparing the deference of area between golden sample and DUT.


Show by percentage
Analysis the power loss by this data.

c29204991141f20b4a10a68d330f1bab.JPG

Differential area comparison

Add up the difference between normal wave and DUT wave call “ Area differential”.


When layer short happened, the inductance reduce(similar the transformer). The wave phase change and the area differential also change. This will show “fail” on the instrument.


However, the parameter might cause deviation because of the deviation of inductance, resonance phase shift. (Silicon steel product such as motor and traditional transformer is not suitable)

 

By calculating and comparing the deference of area between golden sample and DUT. To determine the degree of waveform overlap.
Compare the inductance by this.

85bcd0f1ab7217e094c9f73a6cfc0a17.JPG

Corona comparison

In pulse test, the insulation defect will cause discharge and create corona. This function is able to count the times that corona happened base on the degree of deviation.


Detect the discharge phenomenon on the coil.

78b1022581b01ecb169271ff9e20b1b6.jpg   3c46c84d789fc3a54e99cf00881f09f6.jpg

LAPLACIAN Comparison

Poor insulation quality of the coil results in discharge under high voltage impact, causing rapid changes in the oscillation waveform. By employing the 7750 second-order differentiation algorithm, the maximum discharge capacity is obtained, effectively detecting quality issues related to electrical leakage caused by poor solder joints in the monolithic inductor.

COMP Comparison

By setting an allowable waveform range for the standard wave, this feature can simultaneously determine the
amplitude and phase of the resonant wave. It enhances the detection capability of inter-turn short circuits.

FLUT Comparison

When there is inter-turn discharge in the winding coil, the waveform will exhibit tremors or fluctuations. Therefore, the instrument quantifies the degree of waveform tremors into numerical values for comparison.

SYSTEM

  PLC Remote Control Test、About
  PLC Remote Output Signal PASS、FAIL、HV Output、Testing
  Built-in Storage 200 sets testing waveform
  Power Supply Voltage:98Vac-132Vac 或192Vac-264Vac 
Frequency:50/60Hz ±5%
  Power consumption 45VA
  Environment Temperature:10℃-40℃
Humidity:20-80%RH
  Dimension 430x132x370 mm (W*H*D)
  Weight 7Kg
  Interface

USB Host/Device、RS-232、Remote、LAN

GPIB (Option)

  Display 7" dot-matrix (800*480 )

 

Product Details
7750 Series