Recent Posts

View All
Siglent DF2001A Power analysis deskew fixture
  • Siglent DF2001A Power analysis deskew fixture

Siglent DF2001A Power analysis deskew fixture

DF2001A
Siglent
$456.50
Tax included
Quantity

In-stock, same-day dispatch
Description

To make accurate power loss measurements, you must perform current and voltage channel deskew using the DF2001A deskew fixture. The channel deskew procedure calibrates the time delay between current and voltage probes. This step is certainly important since a small delay in the timing of the voltage and current traces can cause a large error in the instantaneous power reading.

The deskew accuracy is a function of the electrical characteristics of the voltage and current probes as well as the rise time of the signal under test. In general, higher bandwidth probes will allow better rise time fidelity and better deskew resolution.

You need to perform the deskew procedure once initially, and you should re-run the procedure when any part of the hardware setup changes (for example, a different probe, different oscilloscope channel, etc.) or when the ambient temperature changes.

To perform the channel deskew, do the following steps:

1. First, demagnetize and zero-adjust the current probe.

2. Make connections to the DF2001A deskew fixture:

Small Loop
Large Loop
For current probes:

CP4060 (100KHz, 60A)

CP4200 (150KHz, 200A)

CP5050 (40KHz, 50A)

CP4200 (150KHz, 200A)
Connect J2: differential measuring J1: differential measuring
High-voltage terminal terminal
differential probe to either: J7: signal terminal J3: signal terminal
  J6: earth terminal J4: earth terminal

      a. Connect D+ and D- of the high-voltage differential probe to the deskew fixture.

      b. Connect the current probe to the loop with the direction of the arrow pointing towards the current flow.

      c. Make sure the switch on the deskew fixture is set to the appropriate side of the fixture (either “small loop” or “large loop”).

      d. Connect the deskew fixture to a USB port on your oscilloscope or a PC using a USB cable. The USB port supplies power to the deskew fixture.

3. Press the Utility on the front panel to enter the UTILITY function menu.

4. Press the Next Page softkey to enter the second page of the UTILITY function menu. 

Deskew Image 1

5. Press the Power Analyze softkey to enter the ANALYSIS function menu.

6. Press the Signal softkey to enter the SIGNAL setting menu. 

7. Press the Voltage softkey, and then turn the universal knob to select the analogy cannel probing the voltage signal.

8. Press the Current softkey, and then turn the universal knob to select the analogy channel probing the current signal.

9. Press the Deskew softkey to enter the DESKEW function menu.

10. Press the Auto Deskew softkey. When the process completes, you see a message indicating whether the deskew was successful, and if so, the settings being used. 

Deskew Image 5

General, you need to perform the deskew again when part of the test setup changes (for example, a different oscilloscope probe, different channel, etc.) or when the ambient temperature has changed.

Product Details
DF2001A
16 other products in the same category:

Reference: SDG8004A

Brand: Siglent

SDG8000A series function/arbitrary waveform generator

SDG8000A series function/arbitrary waveform generator, maximum 4 analog output channels, 16-bit vertical resolution, maximum 12 GSa/s (interpolation) sampling rate, output frequency up to 5 GHz and maximum modulation bandwidth up to 2 GHz. Maximum storage space of 4G points per channel, providing longer playing time without sacrificing signal bandwidth....

More
Call for availability & lead time

Reference: K-MC1

Brand: RFbeam

K-MC1 Radar Transceiver

Key Features: Support Voltage: 3.3V, 5V; Channels: 2; Opening Angle: H25°x V12°; Typical Detection Range car:150m; Integrated Signal Processing: no; Frequency Band: 24 GHz; Supply Current: 90.00 mA; Typical Detection Range person: 56m; Tuning Range: 300MHz; Size: 65 x 65 x 7

Call for availability & lead time

Reference: SDM4065A-SC

Brand: Siglent

Siglent SDM4065A 6.5 Digits 50000 rdgs/s Digital Multimeter+Scanner Card (SC1016)

The SIGLENT SDM4065A is a 6½‑digit (2,200,000‑count) dual‑display digital multimeter featuring a 5" full‑color touchscreen (800×480) and real‑time True‑RMS measurement for AC/DC voltage (200 mV–1000 V) and current (200 µA–10 A). With up to 50 000 rdgs/s throughput and 0.001 PLC minimum aperture, it delivers both high‑speed and high‑precision performance.

More
Call for availability & lead time

Reference: DJI Matrice 3TD

Brand: DJI

DJI Matrice 3TD combo2

640×512 Infrared Camera with support for UHR Infrared Imaging 1/1.32″ CMOS Wide Camera Secondary 12 MP Telephoto Camera with 56x Hybrid Zoom IP54 waterproof and dustproof rating Extended flight time of up to 50 minutes with 400 battery cycles Built-in RTK Module to facilitate accurate positioning data Six-direction obstacle sensing system

More
Call for availability & lead time

Reference: DJI-Phantom 4 RTK

Brand: DJI

DJI FLYCART 30

Dynamic Aerial Delivery 30 kg Max Payload 28 km Flight Range without Payload 16km Flight range with Full Payload 20m/s Max Speed Delivery Hub software Integration

More
Call for availability & lead time

Reference: DJI-Mavic 3 Enterprise

Brand: DJI

DJI Mavic 3 Multispectral including 1 Year Plus Shield

Ideal For Agriculture & Surveying with 4 × 5MP G/R/RE/NIR Camera Sensors Compact and portable Five cameras including a 4/3”CMOSSensor and 4 x 5MP G/R/RE/NIR Up to 43 minutes of flight time, perfect for longer missions Advanced safety with Omnidirectional obstacle avoidance, Advanced RTH and APAS 5.0 Support for expansion modules including the MЗE RTK...

More
Call for availability & lead time

Reference: DJI-Mavic 3 Thermal

Brand: DJI

DJI Mavic 3 Thermal With 1 Year Care

With 640x512 px Thermal Camera for temperature measurement Compact & portable. 4/3" CMOS wide camera. 56x Hybrid zoom. 45 min max flight time. DJI O3 Enterprise transmission. Centimetre-level positioning with RTK (additional). High volume loud speaker (additional).

More
Call for availability & lead time

Reference: DJI Matrice 3TD

Brand: DJI

DJI Matrice 3TD combo3

640×512 Infrared Camera with support for UHR Infrared Imaging 1/1.32″ CMOS Wide Camera Secondary 12 MP Telephoto Camera with 56x Hybrid Zoom IP54 waterproof and dustproof rating Extended flight time of up to 50 minutes with 400 battery cycles Built-in RTK Module to facilitate accurate positioning data Six-direction obstacle sensing system

More
Call for availability & lead time

Reference: DJI-Matrice 30T

Brand: DJI

DJI Matrice 30T SP SET1 with Battery Station, Care Enterprise Basic Shield and 4pcs Batteries

 640 x 512 px Thermal Camera for Thermal Imaging solution Compact and portable Integrated Wide, Zoom cameras and  infrared cameras with Laser Range finder sensor IP55 ingress protection, and -20°c~50°c temperature operation range Lightweight and portable, for those who are mobile Remote control is tailor-made for enterprise users 41-Min Max. Flight Time...

More
Call for availability & lead time

Reference: K-LD7

Brand: RFbeam

K-LD7 Digital Radar Transceiver

Key Features: Support Voltage: 3.3V, 5V; Channels: 3; Opening Angle: H80°x V34°; Typical Detection Range car:30m; Integrated Signal Processing: Yes; Frequency Band: 24 GHz; Supply Current: 30.00 mA; Typical Detection Range person: 15m; Tuning Range: -MHz; Size: 38 x 25 x 14

Call for availability & lead time

Reference: DJI-Mavic 3 Enterprise

Brand: DJI

DJI Mavic 3 Enterprise With 1 Year Care

Compact & portable. 4/3" CMOS wide camera. 56x Hybrid zoom. 45 min max flight time. DJI O3 Enterprise transmission. Centimetre-level positioning with RTK (additional). High volume loud speaker (additional).

More
Call for availability & lead time

Reference: K-XC1_SMA

Brand: RFbeam

K-XC1_SMA Digital Distance Radar

Key Features: Support Voltage: 24V; Channels: 2; Opening Angle: H-° x V-°; Typical Detection Range car:-m; Integrated Signal Processing: Yes; Frequency Band: 24 GHz; Supply Current: 300.00 mA; Typical Detection Range person: -m; Tuning Range: 4000 MHz; Size: 89 x 77 x 19

Call for availability & lead time

Reference: APV1181X

Brand: AppVision

APV1181X monitor control radar module

Key Features: Support Voltage: 3.6V-5.5V; Channels: 1; Opening Angle: H55°x V55°; Detection in liner direction of moving objects  : >8m; Detection in liner direction of static objects  : >4m; Frequency Band: 24 GHz; Supply Current: 20mA(average); Modulation: FMCW; Output format: Serial port ASCII Size:5.2cm x 0.7cm

Call for availability & lead time